Cable fault tester is a comprehensive set of equipment. It is used for testing of open, short circuit, grounding, low resistance, high resistance flashover and high resistance leakage faults of power cables, as well as accurate testing of open circuit and short circuit faults of coaxial communication cables and local telephone cables. Can also test the cable path, depth, and radio wave speed, verify the cable length, etc., and can establish cable files for daily maintenance and management.
Cautions during use of the cable fault tester :
1. During the pulse method test, be careful to get rid of all the equipment in the office and make measurements on the outermost line.
2. When using the flash method test, the trigger mode switch must be placed in the "flashover" position.
3. When using direct flash or flash test, pay attention to personal safety and equipment safety. Must be connected to the ground.
4. After the flashover test is completed, cut off the power supply, remove the connection line between the instrument and the high-voltage test device, and discharge the charge stored in the high-voltage capacitors and cables. When discharging, the current limiting resistor R should be added to limit the discharge current so that the current can be slowly discharged. After the voltage on the capacitor is reduced, the resistance in the discharge circuit directly to ground is zero, and the instantaneous discharge current can be as high as several hundred amps. Equipment or personal accident.
5. During the direct flash test, care must be taken to monitor the leakage current of the fault. If the current suddenly increases and the flashover phenomenon does not occur, the test voltage should be reduced immediately and the flashover test should be used instead.
The smoothness of the cable fault tester system and the power transmission depend on the normal operation of the cable line. Once obstacles occur on the line, it will cause interruption of communication and power. If failures cannot be detected and eliminated quickly, it will cause great economic losses and adverse social impact. Therefore, the maintenance personnel should pay attention to ensure that the cable fault tester can operate normally during the work process.
Finally, attach the specific parameters of the currently used MS-801C cable fault tester for your reference:
1. Test distance: single-ended test distance ≤ 10 km
2. The shortest test distance (blind): less than V/15 (m)
Among them: the speed of V-wave propagation in the cable under test
3. Test error: Relative error: ≤±2%; Absolute error: Fault point within ≤15 meters
Fault point is more than 1000 meters ≤ 20 meters
4 reading resolution: V/60 meters
Where: V-wave propagation speed in the cable under test. Such as: "oil-impregnated paper cable", the radio wave propagation speed of 160m / us The minimum reading of the instrument is 2.66 meters, that is, every time the cursor moves on the screen, the reading changes by 2.6 meters.
5. Power: AC 220V±10% 50Hz
6. Environmental Conditions: Temperature: 0°C~50°C Relative Humidity: 80%±5%
7. The host volume: 350 × 250 × 200 (mm)
8. Host weight: 5kg
respected user:
Thank you for your attention to our products. In addition to this product introduction, our company also has vacuum degree tester, infrared thermometer, dielectric loss tester, high voltage test transformer, vacuum oil filter, high current generator, etc. If you are interested in our products, welcome to inquire. Thank you!

Truck Tire Changer

Truck Tire Changer with its scientific and practical design is excellent value and can meet the needs of regular truck tire service.

Truck Tire Changer,Semi Truck Tire Changing Machine,Truck Tire Machine,Automatic Truck Tire Changer

Yingkou Junyuan Machinery Manufacturing Co., Ltd , https://www.yuanmech.com